This paper presents effects of housing electricity and heat source equipments. We studied about energy saving effects of 4 equipments, CO2 Heat Pump water heater(CO2-HP), Micro Gas Engine Co-Generatio...n System(GE-μCGS), Polymer Electrolyte Fuel Cell Co-Generation System(PEFC-CGS), and Solid Oxide Fuel Cell Co-Generation System(SOFC-CGS). As the result, we have found that energy consumption and CO2 emission reduction rate is the highest in the case of SOFC-CGS. Energy consumption is reduced by 17-20% using SOFC-CGS on Electric Power Load Tracking Operation, and 44-47% on Rated Operation. And CO2 emission is reduced by 6-21% on Electric Power Load Tracking Operation and 23-47% on Rated Operation.続きを見る
|