<紀要論文>
圧力センサの取付方と壁面変動圧力の測定値との関係

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
出版タイプ
アクセス権
JaLC DOI
関連DOI
関連URI
関連情報
概要 By reviewing the detailed investigations carried out on time-fluctuating wall pressure measurements in unsteady flow field, the selection of pressure transducer, installation method of it and data red...ucing process are investigated. Moreover, in present paper is experimentally investigated the influence of pressure transducer installation method on the measurement results. In results, the levels of the time-averaging result of wall pressure and rms value of the fluctuating wall pressure show lower value in the submergence case than flushness installation of pressure transducer. Its influential degree of time-averaging value mainly becomes low as increasing the diameter of pressure measuring hole size, however, it becomes clear that the rms value is almost independent of the installation method of transducer.続きを見る