<departmental bulletin paper>
Compressive Loading Test of Brick Masonry which Constitutes the Kyushu University Headquarters Building 1 and 3

Creator
Language
Publisher
Date
Source Title
Vol
First Page
Last Page
Publication Type
Access Rights
JaLC DOI
Abstract The objective of this study is to grasp the mechanical characteristics to compressive loading about the unreinforced brick masonry extracted from the Kyushu University Headquarters Building 1 and 3. C...ore and prism specimens for the compressive loading test were extracted from the walls of the two unreinforced brick masonry buildings, and were made with the bricks and mortar whose strength were similar to those of the actual masonry structure's components. As a result of the loading tests, some basic mechanical characteristics to compressive loading about the brick masonry were clarified, for instance, compressive strength, stress-strain relations, apparent Young's modulus and so forth. And it was found out that the compressive strength of the actual brick masonry can be affected from the filling condition of the mortar joint.show more

Hide fulltext details.

pdf p101 pdf 847 KB 338  