Abstract Already the authors have reported that wind pressure on surface of a gable roof body caused by a short-time rise gust grew much bigger than in a steady flow. In this paper, we focused on wind pressure... on pendent eaves of gable roof structure. In the result of our gusty wind tunnel test, it was found that the overshoot of wind pressure occurred on top and bottom faces of the pendent eaves. And the intensity of overshoot wind force, acting on eaves, which is calculated as the difference between pressure on top and bottom faces of the eaves, depended on the location of measuring point strongly.show more