<学術雑誌論文>
フランジ継手を有する鋼管はり部材の動的載荷性能実験

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
出版タイプ
アクセス権
関連DOI
関連URI
関連HDL
概要 This paper presents an experimental approach on the dynamic load-carrying capacity of the steel pipe beam with a flange joint. First, the current status of steel pipe beams with joints is presented. S...econd, the static and dynamic (rapid-speed) load tests are performed for the steel pipe cantilever beams with a flange joint by changing the loading position. The test results showed that the failure mechanism of flange joint by dynamic load was remarkably damaged rather than the one by static load at the loading position near the flange joint. This cause may be due to the effect of repeated loads and strong shearing force. On the other hand, the damage at the loading position far from the flange joint was only flexural-tension and no difference between static and dynamic loads.続きを見る
目次 1.緒言
2.鋼管継手の現行設計法と損傷実態
3.載荷実験
4.実験結果
5.継手部の検討
5.結 論