The SRB-DUP(Steel Reinforced Brick based on Distributed Unbond Prestress theory) structure can be used not only as the main load bearing structural member of a building, but also as a friction damper ...for controlling vibration of the building with other main structural system. In this study, high-speed horizontal loading tests were performed on the proposed connections between the SRB-DUP walls and steel frames. The horizontal load-displacement relationship of the connection between the SRB-DUP wall and steel frame was applied to static load incremental analysis and time history response analysis of a real building(Satellite Communications Laboratory, Kyushu University, Fukuoka, Japan). As a result of the experiments and analyses, the frictional damping effect of the SRB-DUP wall is high, even the case where low prestress is given to the structure at each connecting point between wall and frame.続きを見る
|