作成者 |
|
|
本文言語 |
|
出版者 |
|
|
発行日 |
|
収録物名 |
|
巻 |
|
開始ページ |
|
終了ページ |
|
出版タイプ |
|
アクセス権 |
|
JaLC DOI |
|
関連DOI |
|
|
|
関連URI |
|
|
|
関連情報 |
|
|
|
概要 |
Generally, a transmission tower is designed statically based on Japanese civil standard: Design Standard on Structures for Transmission, JEC127-(1979). However a special tower, e.g. very high tower an...d a tower under gusty wind, is designed dynamically using dynamic response analysis. For suitable dynamic design, it is important that the analysis results and actual phenomena are consistent. In this paper, we compared vibration test results of an actual transmission tower and these numerical results using dynamic analysis program. So, we confirmed that these results show same vibration characteristics. These results show availability of the dynamic analysis program for transmission tower design.続きを見る
|