作成者 |
|
|
|
|
本文言語 |
|
出版者 |
|
|
発行日 |
|
収録物名 |
|
巻 |
|
開始ページ |
|
終了ページ |
|
出版タイプ |
|
アクセス権 |
|
JaLC DOI |
|
関連DOI |
|
|
|
関連URI |
|
|
|
関連情報 |
|
|
|
概要 |
The objectives of this study are to propose a sustainable connecting method between wall and frame of structure, and to clarify the fictional damping effect of the connection. The proposed connection ...absorbs the energy of external force, such as seismic force, by slip with friction between wall and frame. Additionally, walls and frames are not bonded to each other at the proposed connections, making it possible to disassemble members once assembled, so that they can be easily reused or recycled. High-speed horizontal loading tests were performed on the proposed connections between walls and steel frames. Types of walls are precast concrete panel, ALC(Autoclaved Lightweight Concrete) panel and reinforced concrete block wall. As a result of the experiments, it was found that precast concrete panel is the most suitable for the proposed connecting system, and that reinforced concrete block wall has potential to improve the damping performance by finishing its top face appropriately.続きを見る
|