作成者 |
|
|
|
|
本文言語 |
|
出版者 |
|
|
発行日 |
|
収録物名 |
|
巻 |
|
開始ページ |
|
終了ページ |
|
出版タイプ |
|
アクセス権 |
|
JaLC DOI |
|
関連DOI |
|
|
|
関連URI |
|
|
|
関連情報 |
|
|
|
概要 |
This paper presents the effctive operation methods and the energy conservation effects of housing Polymer Electrolyte Fuel Cell Co-Generation System(PEFC-CGS) with an electric storage capacitor. We bu...ilt the model-based simulation program to calculate the energy budget in the case that PEFC-CGS and Storage System were introduced to detached houses considering specifications of real PEFC-CGS and assumed Storage System. As a result of model-based simulations, we found that DSS(Daily Start and Stop) operation to follow the power loading was the most effective method. It is the calculation result of winter 2 weeks that effect could be comfirmed most. 27% of CO2 emissions discharge, and 19% of the amounts of the primary energy consumption were reduced.CO2 of 7.16kg-CO2 and the primary energy of 100MJ were reduced more than the case that only PEFC-CGS was introduced.The capacity of the Storage System of 600Wh should be necessary to get this effect.続きを見る
|