<会議発表論文>
Continuous-flow of Nanoscale Zero Valent Iron based system for phosphorus removal

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
会議情報
出版タイプ
アクセス権
JaLC DOI
概要 In this study, the removal performance of NZVI for phosphorus under different five condition such as 1) open (with Polishing Unit (1a) and without one (1b)), 2) full aerobic (air flow=1.2L/min. (2a) a...nd 1L/min. (2b)) and 3) full anaerobic conditions (nitrogen flow=3L/min) were analyzed. The initial phosphorus concentration and feeding rate were maintained each approximately 25 mg P/L and 20 ml/min. In each condition, the reactor phosphorus removal rates for initial 3 hours were 77.6 ± 10.2% (1a), 96.3 ± 1.7% (1b), 95.6 ± 1.4% (2a), 95.5 ± 2.3% (2b) and 96.8 ± 2.0% (3). From these results, there are no big differences between them. However, all of the rates decreased to about 50 to 80% after 12 hours. The effluent total iron concentration from the reactor was also analyzed and the correlation with the effluent phosphorus concentration was calculated. As a result, correlation coefficient was R^2=0.963 (2a), R^2=0.897(2b), R^2=0.885(3) respectively, and it was confirmed that there is positive correlation.続きを見る

本文ファイル

pdf p163 pdf 530 KB 260  

詳細

EISSN
レコードID
主題
登録日 2018.02.22
更新日 2019.08.01

この資料を見た人はこんな資料も見ています