<紀要論文>
Dc Electrical Breakdown of Liquid Nitrogen under Simulated Quench State in Pool Cooled High T_c Superconducting Power Apparatus Pt. 2. Experimental Study of Bubble Behavior and Bubble-Triggered Breakdown Characteristics

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
出版タイプ
アクセス権
JaLC DOI
関連DOI
関連URI
関連情報
概要 In the Part 2, observations of thermally induced bubbles and measurements of breakdown characteristics with a cylinder-to-plane gap are described. The experimental results show that observed bubble be...havior agrees very well with the analytical one described in the Part 1 and that breakdown voltage in liquid nitrogen in the presence of thermal bubbles depends on activity of boiling and falls down to the value in nitrogen gas at normal boiling temperature. The reduction in breakdown voltage is mainly caused by elongated bubbles in the shortest gap region in smooth cylinder-toplane gap. Fins on the cylinder reduce the breakdown voltage due to their field enhancement effect, but the reduction by thermal bubbles is minimized if the fin is machined so as to guide electrically the bubble along the groove between fins from a higher external field region to a lower one.続きを見る

本文ファイル

pdf p035 pdf 3.84 MB 162  

詳細

PISSN
EISSN
NCID
レコードID
査読有無
主題
登録日 2015.04.09
更新日 2020.11.02

この資料を見た人はこんな資料も見ています