<紀要論文>
水平細管内における純冷媒HFC134aの蒸発を伴う流動特性

作成者
本文言語
出版者
発行日
雑誌名
開始ページ
終了ページ
出版タイプ
アクセス権
JaLC DOI
概要 In the present study, the characteristics of flow pattern are investigated experimentally for evaporation of pure refrigerant HFC134a in a capillary tube of 1.2mm I.D. The capillary tube consists of a... heating-copper tube section and a glass-tube section, which is located at the right after the outlet of the heating section. The flow pattern is observed through the glass tube section in the ranges of mass velocity of G=80~1260kg/(m^2 s) and vapor quality of x=0.008~0.975 at a constant pressure of 920 kPa. The flow patterns observed are the bubble flow, the plug flow, the slug flow, the wavy annular flow and the annular flow. These flow patterns are typical for a relatively large diameter tube used as the heat transfer tube in commercial refrigeration and air-conditioning systems. However the transition points between each flow pattern are different from the modified Baker map and the Taitel-Dukler map, which are proposed for a relatively large diameter tube.続きを見る

本文情報を非表示

KJ00004507879 pdf 1.39 MB 538  

詳細

レコードID
査読有無
関連情報
ISSN
NCID
タイプ
登録日 2009.04.22
更新日 2017.06.07