| 作成者 |
|
|
|
|
|
|
|
|
|
|
|
| 本文言語 |
|
| 出版者 |
|
| 発行日 |
|
| 会議情報 |
|
| 出版タイプ |
|
| アクセス権 |
|
| 権利関係 |
|
| 関連DOI |
|
| 関連DOI |
|
|
|
|
|
|
|
| 関連DOI |
|
| 以下を参照 |
|
| 関連ISBN |
|
|
|
|
|
|
|
| 関連HDL |
|
|
|
|
|
|
|
| 関連HDL |
|
| 関連ISBN |
|
| 関連情報 |
|
| 概要 |
The kelvin-source packages are becoming popular for high-power ultrafast switching devices to reduce the common source inductance (CSI), which induces the noise voltage in the gating circuit at the tr...ansitional change of the drain current and causes false triggering. Despite its importance, however, the actual measurement of CSI has not been reported for kelvin-source packages due to their small inductance values. This paper measured the CSI of typical kelvin-source package TO-247-4L. The result revealed that the CSI of this kelvin-source package ranged 0.2nH–0.7nH, which cannot be neglected at a switching speed greater than 1A/ns. Furthermore, this variation in CSI was found to arise from the magnetic coupling between the bonding wires of power source and gating source, implying that separating the bonding wires can further reduce the CSI.続きを見る
|