<紀要論文>
壁面局所熱伝達係数の遠隔測定法

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
出版タイプ
アクセス権
JaLC DOI
関連DOI
関連URI
関連情報
概要 The present paper describes an experimental method to measure local heat flux from a distance. The method is based on the fact that when a wall is heated locally, the wall temperature rise depends on ...the local heat transfer coefficient at that point. In the experiment, the wall was heated by a power laser and the temperature rise was measured by an infrared spot thermometer. Transient heat conduction in a wall was numerically solved for a heated location. The integral of the temperature rise is found to be the quantity most sensitive to variation in heat transfer coefficient. If the integral value is measured within a 2% error margin, the heat transfer coefficient could be evaluated within a margin of 10% for acryl. For metals having high thermal diffusivity, however, error is above 80%. Automatical measurement with the aid of a personal computer made it possible to evaluate forced convection heat transfer coefficient of a flat plaster plate within an accuracy of 20%.続きを見る

本文ファイル

pdf KJ00004507495 pdf 785 KB 605  

詳細

レコードID
査読有無
ISSN
NCID
タイプ
登録日 2009.04.22
更新日 2020.11.17

この資料を見た人はこんな資料も見ています