<departmental bulletin paper>
Non-Balanced Tension of Conductors of Transmission Towers Running along Supports of Different Height

Creator
Language
Publisher
Date
Source Title
Vol
First Page
Last Page
Publication Type
Access Rights
JaLC DOI
Related DOI
Related URI
Relation
Abstract A transmission tower is submitted to wind loads acting on the tower body and the conductors. A vertical difference of adjacent supports of conductors as well as a different distance between adjacent t...owers generates non-balanced tension of conductors, which acts on the tower as ‘non-balanced tension load’. We studied the static and dynamic properties of non-balanced tension of conductors which are running along supports of different height under strong winds. We concluded as follows; (1) Conductor’s non-balanced tensions acting on a transmission tower increased with vertical difference of adjacent supports. (2) The gusty wind response of a tower was bigger than an estimated value based on Design Standard on Structures for Transmission, JEC-127(1979).show more

Hide fulltext details.

pdf jaud20_p033 pdf 1.03 MB 5,289  