Creator |
|
|
Language |
|
Publisher |
|
|
Date |
|
Source Title |
|
Vol |
|
Issue |
|
First Page |
|
Last Page |
|
Publication Type |
|
Access Rights |
|
Crossref DOI |
|
Rights |
|
Abstract |
Modified solar water heating system (MSWHS) of 200L is a modification over the existing technologies of flat plate collector and evacuated tubular collector. In the present communication, MSWHS has be...en modeled using MATLAB R2014a and evaluated for the climatic data of Allahabad, India for the year 2015-16. The maximum temperature of water in the storage tank and tubes of collector have been found to be 85 ºC and 89 ºC in the month of May respectively. The parametric study has also been carried out. Further, the study has also been extended for life cycle assessment and cost analysis of the setup. The embodied energy of the setup is found to be 1658.73kWh.show more
|