<学術雑誌論文>
Single-Detector CTを用いた腹部骨盤CTにおける造影剤低容量化の試み : イオヘキソール300(オムニパーク300,100mlシリンジ製剤)とイオベルソール320(オプチレイ320,75mlシリンジ製剤)を用いて

作成者
本文言語
出版者
発行日
収録物名
開始ページ
終了ページ
出版タイプ
アクセス権
JaLC DOI
関連DOI
関連URI
関連HDL
概要 Purpose : The steadily elevating cost of the contrast-enhanced CT has been a problem in last decade. One approach to curtail the cost is to reduce the amount of contrast media (CM). The purpose of thi...s study was to examine the possibility of reducing the volume of CM in single-detector CT (SDCT) without compromising diagnostic ability. Materials and Methods : One hundred ml of Iohexol 300 and 75 ml of Ioversol 320 were compared in a prospective CT study about their imaging quality. One hundred patients were randomly divided into two parallel groups (A and B). The former agent was used for group A and the latter for B. CT attenuations of the aorta, central vein, spleen and kidney were measured and each imaging quality was reviewed by three radiologists. Results : CT attenuations and the imaging quality were significantly superior (p <0.05) in A group, however, comparing in the condition under 50 kg patients, they showed no significant differences and the quality was tolerable for diagnosis in both group. Conclusion : This demonstrates the difficulty to perform the high-quality CT with a reduced CM in SDCT. However, this does not negate the diagnostic ability of low dose of CM, but reflects the importance of determining the acceptable lowest doze of CM for diagnosis.続きを見る

本文ファイル

pdf fam95_5_p118 pdf 19.0 MB 422  

詳細

PISSN
NCID
レコードID
査読有無
関連PubMed ID
主題
タイプ
登録日 2012.06.04
更新日 2021.07.28

この資料を見た人はこんな資料も見ています