<departmental bulletin paper>
Improvement of Wind Resistant Reinforcements for Steel-Tube Transmission Towers

Creator
Language
Publisher
Date
Source Title
Vol
First Page
Last Page
Publication Type
Access Rights
JaLC DOI
Related DOI
Related URI
Relation
Abstract The parallel-member attachng is a useful measure to renforce steel-tube transmission towers against wind loads. In some cases, however, an original method of fixing the parallel members is not availab...le. So the authors have developed new three devices: a reinforced band, an improved reinforced band and a double reinforced band to fix the parallel members. These devices make use of frictional stress of the band against the main posts of the steel-tube transmission tower. The compression-tensile tests of those reinforced members showed satisfactory validity of the parallel-member attachnent method by the double reinforced band. In addition, a wind tunnel test was conducted to confirm aerodynamic characteristics of the reinforced member by the parallel-member attaciment. The test results indicated that the drag factor of the reinforced member was less than 0.2 and was dependent on the wind direction.show more

Hide fulltext details.

pdf jaud006_p085 pdf 5.53 MB 577  