Abstract This paper provides the standard push-out test results and discusses the resistance behavior between the steel beam and the concrete slab using burring shear connectors. The following results have bee...n obtained: it has been shown clearly the rate of resistance force (bearing, shearing and adhesion) of the burring shear connector. In the burring centre-to-centre spacing of 100 to 300 mm, it has become clear that there is no influence which it has on the maximum strength and the stiffness.show more

Hide fulltext details.

pdf jaud024_p107 pdf 853 KB 1,184  