作成者 |
|
|
|
|
|
|
|
本文言語 |
|
出版者 |
|
|
発行日 |
|
収録物名 |
|
巻 |
|
号 |
|
開始ページ |
|
終了ページ |
|
出版タイプ |
|
アクセス権 |
|
JaLC DOI |
|
関連DOI |
|
|
|
|
関連URI |
|
|
|
|
関連情報 |
|
|
|
|
概要 |
The thermal environment in a cavity space between two buildings, called an urban canyon, should be analyzed as a unit of urban thermal environment. The field measurement of the thermal environment wa...s carried out in the housing site which consists of 5 storied apartment buildings. Global solar radiation and wind speed were measured above the roof of the windward building as the reference value. Air temperature, globe temperature, and wind speed were measured at 4 points in an urban canyon. The solar heat gain on the wall and the ground surface in the urban canyon is calculated from the reference global solar radiation data, considering mutual reflection in the urba canyon. Globe temperatures are calculated from the estimated data mentioned above. These calculated values agree well with the measured ones.続きを見る
|